The QXL series small submersible pump (dedicated to vacuum preloading) is designed based on the harsh usage conditions of vacuum preloading soft foundation treatment. It is a product with good sand discharge performance and high insulation level. The flow rate and outlet pressure performance parameters are well matched with the jet pump, and the system efficiency is high. It is professionally designed for water prevention, safe and reliable, and has a long fault free service cycle. It is the preferred equipment in the vacuum preloading soft foundation treatment industry due to its convenient use and other characteristics. It can also be widely used for drainage in industrial and mining enterprises, water extraction in hilly areas, and other purposes. The pump medium is similar media such as clean water and fresh seawater.


Submersible vacuum preloading equipment


Operating conditions for submersible vacuum preloading equipment

1. Rated voltage of motor: 380V ± 5%. Three phase AC power with a frequency of 50Hz.

2. The temperature of the conveying medium shall not exceed 40C.

3. The pH value of the conveying medium is 4-10

4. The volume ratio of solid matter in the conveying medium is ≤ 0.5%.

5. The density of the conveying medium is ≤ 1.05 x 10kg/m3.

6. More than 4/5 of the pump height should be submerged in water.


Structural characteristics

1. The motor part adopts an F-level insulation protection level of IP68, which can operate continuously and reliably for a long time.

2. The motor shaft is equipped with a double oil chamber structure to ensure the safe operation of the water pump motor.

3. The motor casing components and the entire machine have undergone secondary airtightness testing, fully meeting the demanding working environment


Environment.

4. The pump is equipped with a double sealing chamber and a pressure reducing sand discharge structure, greatly extending the service life of the seal.


5. The motor rotor and impeller undergo strict sanitation inspection, which reduces the vibration and noise of the water pump during operation.


6. Convenient maintenance: After disconnecting the power, loosen the connecting bolts, press the base -+pump body ->impeller -+lower oil chamber -+upper part


Oil chamber motor sequential disassembly and maintenance.


7. The impeller has been optimized for high efficiency and durability.


8. The static sealing surface adopts an O-ring to ensure no leakage.


9. Equipped with a cooling water guide pipe, connecting the guide hose can guide the external cooling water cooling water pump motor.


Transportation, installation, and usage precautions

1. During the transportation of the water pump, the handle above the pump must be used and it is not allowed to pull the cable.


2. During transportation, the cable must be coiled above the pump and not subjected to compression to avoid cable injury.


3. Before installing and using the water pump, it is necessary to carefully read the following clause 4 to avoid equipment damage caused by inconsistent usage conditions with the specified conditions of the water pump.


4. Before starting the water pump after installation, the following checks should be carried out:


a. Use a 0-500V megohmmeter to check the insulation resistance of the three-phase winding of the main frequency line to the ground, and the z-value should not be less than 50M0 (cold state).


b. The cable must not be squeezed or damaged. If there is any, it must be disconnected and reprocessed by wrapping it with waterproof tape. The processed joint needs to be immersed in water for 12 hours before using a 0-500V megohmmeter to check the insulation resistance to ground.


c. The power supply voltage must be within the rated voltage range (380V ± 5%); The damage to the water pump motor caused by voltage exceeding or falling below the rated voltage range is not within the scope of product quality warranty. If the water pump is installed at a distance from the main control cabinet


Submersible vacuum preloading equipment

performance parameter

Submersible vacuum preloading equipment



Appearance and installation


Submersible vacuum preloading equipment



Assembly instruction diagram:



Submersible vacuum preloading equipmentSubmersible vacuum preloading equipment

news.related_news

  • 菜单

Jiangsu Yuanzhirui Electric Pump Industry Co., Ltd. is jointly established by Lianyungang Ruibao Electric Motor Co., Ltd. and Lianyungang Liyuan Pump Industry Co., Ltd. The company focuses on producing vacuum preloading equipment, vacuum preloading submersible pumps......

Contact information

Contact person: Tan Rui

Mobile phone: 18961356726

Fax: 0518-86412776

Email: rbmotor@ 163.com

Website: www.jsyzr.com

Address: Industrial Cluster Zone, Jiaoshang Town, Ganyu District, Lianyungang City, Jiangsu Province